Aktuelles Forschung Mitarbeiter Studium Informationen
Language | Sprache  
Forschung
>> Nanotechnologie
>> Rastersonden-
     mikroskopie
>> Technologie
>> Materialien
>> Veröffentlichungen
 

Einzel-Elektronen-Transistor - Michael Skender
With the further down scaling of conventional MOS-technology physical limits will be reached. Therefore there is a need for new concepts for future nanoelectronics. One interesting effect, which might be exploited in new nanoelectronic devices is Coulomb blockade. The approach used in our group for the fabrication of such nanostructures in thin films is by lithography and etching. Here an island is realized between two electron reservoirs, source and drain, where the island is connected to the reservoirs by small constrictions (see fig. 1). If the width of these constrictions is smaller than the Fermi wavelength lF of the electrons in the reservoirs the constrictions will form a tunneling barrier. In metals the Fermi wavelength is very small, in case of Au, lF = 0.5 nm. The realization of constrictions on this scale is beyond any lithographic technique. However, the Fermi wavelength strongly depends on the carrier densitiy and is therefore much larger in semiconductors (e.g. 20 nm in Si at a carrier density of 1·1018 cm-3). The realization of these dimensions in semiconductors is feasible. We have fabricated several silicon single and multiple dot structures, in both mono- and polycrystalline silicon on insulator (SOI) material. In these structures we have demonstrated Coulomb blockade effects at 4.2K.

Mikrosäulenarrays - Helmut Weigand, Birgit Schröppel
Parallel e-beam lithography using the microcolumn concept has been proposed by Chang et. al. [1] as one way to decrease the time for fabrication of nanostructures for integrated circuits. For parallel e-beam lithography miniaturization of the electron optical system is required. Key components of such a system are electrostatic lenses, electrostatic double deflectors and electron detectors. Electrostatic lenses typically consist of three electrodes, separated by insulating spacers. Therefore the lenses need to be reduced in size and placed electrically isolated within an array. Up to now only single column systems have been achieved. In most systems silicon membranes are used as electrodes of the electrostatic lenses and they are supported by silicon as carrier material. With this technique it appears to be difficult to realize an array of electrostatic lenses with electrical isolation between the lenses. We propose the use of borosilicate glass as a carrier material which also acts as insulator and spacer. With this material it is possible to integrate several electrically isolated electrodes, even multipole electrodes, contact pads and interconnections into one surface. The main process steps for one electrode-array are as follows. The structure of one electrode-array is first etched into a wafer with a 2.5 µm thick, highly boron doped epitaxial layer using RIE and a Cr-mask. After stripping the mask a borosilicate glass is connected to the epitaxial layer by anodic bonding. Holes are drilled in the glass by mechanical techniques before bonding. The wafer is finally etched down to the epitaxial layer by a wet chemical etching process.

Research in this working group concentrates on:
  • Realization of multiple column array of miniaturized electron optical systems
  • Development of a low profile detector for low energy backscattered electrons

[1] T.H.P.Chang, D.P.Kern, L.P.Muray; J.Vac.Sci.Technol. B 6 2743 (1992)


Cantileverarrays als Gas- und Biosensoren - Andreas Heeren
A chemical sensor for detecting gas molecules consists of a sensitive layer and a transducer. Analyte particles interact with the sensitive layer of the sensor, resulting in a change of physical properties like conductivity, capacity or mass. A mass sensitive transducer transforms physical and chemical reactions of the analyte with the sensitive layer into a mechanical response. Micromechanical beams (cantilevers) are candidates as mass sensitive transducers for future complex sensor systems. This is due to the reduced geometrical dimensions compared to conventional devices such as the quartz crystal microbalance (QMB) and the possibility of integration with microelectronics. To detect gas molecules, the cantilever is coatet with a sensitive layer and the response to the analyte molecules is obtained by measuring its resonant frequency shift due to the additional mass loading by the absorption of gas molecules. In order to detect a broader variety of gases, the cantilevers in the array have to be coatet with different sensitive layers showing specific sensitivity to these gases. Furthermore, an optical detection arrangement for a simultaneous readout of the array has been established. Measurements of the resonance behavior of differently coated cantilevers exposed to a mixture of gases have demonstrated that our approach is capable of detecting and analyzing the composition of a gas mixture [1].

[1] B.H. Kim, M. Maute, F.E. Prins, D.P. Kern, M. Croitoru, S. Raible, U. Weimar, W. Göpel Parallel Frequency Readout of an Array of Mass-Sensitive Transducers for Sensor Applications Microelec. Eng., 53 (2000) 229-232


Neue Materialien und Prozesse für die Elektronenstrahllithographie - Holger Sailer
Linien aus Calixaren - Resist

Biochemische Synthese auf metallischen Nanostrukturen - Holger Sailer
Ziel dieses Bmbf-Projekts ist die kontrollierte Synthese kurzer DNA-Stränge auf metallischen und halbleitenden Nanostrukturen. Die Synthese soll durch optische Anregung spezifischer Resonanzen der Nanostruktur mittels fs-Laserpulsen an chemisch auf diesen Strukturen gebundenen Ausgangsmolekülen induziert und mit nanoanalytischen Methoden charakterisiert werden. DNA ist eine sehr stabile biologische Molekularstruktur, deren elektrische Eigenschaft zwischen einem Leiter bis hin zu einem Halbleiter mit großer Bandlücke variieren kann (H. W. Fink. et al., 1999, D. Porath et al., 2000). Die Stabilität und die vermuteten elektrischen Eigenschaften machen DNA zu einem idealen Modellsystem zur Studie von Übergängen in Molekül/Leiter- und Molekül-/Halbleiter-Systemen. Die Untersuchung grundlegender physikalischen Mechanismen der Molekül/Substrat-Wechselwirkung sind bei ein wesentlicher Aspekt dieses Projekts. Ziel ist die Optimierung der Synthese kurzer DNA-Stränge auf den Nanostruktur-Oberflächen. Dies geschieht insbesondere durch geeignete Wahl von Material und Geometrie der Nanostrukturen. Die so gewonnenen Erkenntnisse sind wichtig im Hinblick auf die sich entwickelnde DNA-Chip-Technologie und könnten diese maßgeblich beeinflussen. Projektpartner sind das Max-Born-Institut in Berlin sowie das EMBL in Heidelberg.


Spinpolarisierter Elektronen Transport in Si-Nanostrukturen - Carsten Kentsch
Spin-Zustände in Halbleiterstrukturen haben in letzter Zeit große Beachtung erfahren, da sie sich prinzipiell als Quanten-Bits (qubits) in Quanten-Computern eignen. Spin-polarisierte Elektronen finden sich in den Randzuständen zwei-dimensionaler Elektronengase (2DEG). Sie bilden sich in hohen Magnetfeldern (Quanten-Hall-Regime), wenn sich die Landau-Niveaus zum Rand der Probe hin auf Grund des elektrostatischen Einschlusses verbiegen. Hier sollen der Transport in und die Streuung zwischen Spinzuständen in Siliziumstrukturen (Inversionsschichten, Si-Ge Heterostrukturen) untersucht werden. Durch eine Kombination dieser Strukturen mit Quanten-Punkt-Kontakten können verschiedene Landau-Niveaus unterschiedlich beeinflußt werden und auf diese Weise der Transport durch solche Zustände sowie die Streuung von Elektronen zwischen den Kanälen detektiert werden. Ähnliche Experimente wurden bisher nur in GaAs durchgeführt und es wurde eine starke Streuung der Elektronen durch die Wechselwirkung mit dem Kerndrehimpuls von sowohl Ga als auch As beobachtet. Da das Hauptisotop von Si keinen Kerndrehimpuls besitzt, ist zu erwarten, dass die Wechselwirkung mit dem Grundmaterial viel geringer ausfällt, andererseits aber die Wechselwirkung mit gezielten Verunreinigungen eine Rolle spielen könnte.


Nano Pinzetten - Marius Blideran
kein Text
 